Undetermined Problems

The diagnostic problems does not identify which devices fail, which devices are incorrectly installed, whether a short circuit happens, or whether the system is inoperative.

NOTE: Verify if all devices attached are supported by the computer.

NOTE: Verify if the power supply used at the time of failure is operating correctly. You can refer to "Power System Check".

Follow the procedures below to isolate the failing FRU. Do not isolate non-defective FRU.

  1. Power off the computer.
  2. Visually check the devices. If any problems are found, replace the FRU.
  3. Remove or disconnect all of the following devices:
  • Non-Acer devices
  • Printer, mouse, and other external devices
  • Battery Pack
  • Hard disk drive

□ DIMM

  • CD-ROM / Diskette drive module
  • PC cards
  1. Power on the computer.
  2. Determine if the problem has been resolved.
  3. If the problem does not recur, reconnect the removed devices one at a time until you find the failed FRU.
  4. If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU.
  • System board
  • LCD assembly

Jumper and Connector Location

Chapter 5

Top View

Rj45 Connector Locator

No.

Description

No.

Description

1

DC-in jack

2

USB connector

3

CRT connector

4

RJ11 & RJ45 connector

5

MDC module connector

6

MDC board connector

7

Main battery connector

8

ODD connector

9

Mini PCI slot

10

CPU

11

North bridge

12

DIMM slot

13

South bridge

14

HDD connector

No.

Description

No.

Description

15

Line-in jack

16

Microphone-in jack

17

Line-out jack

18

Cardbus controller

19

USB connector

20

LAN controller

21

BIOS ROM

22

RTC battery connector

23

5-in-1 card reader

0 0